Looking for a SoftLok Standalone Dongle.not found.
TUFLOW Engine Not licensed or no local licences free. WIBU Dongles Only = OFF ! If set to ON, searches for WIBU dongles only. WIBU Retry Count = 0 ! Number of times to retry for a licence at start of simulation. Simulations Log Folder = C:\BMT_WBM\log ! Path or URL to global simulations log folder. "C:\BMT_WBM\TUFLOW_Dongle_Settings.dcf" does not exist - default settings assigned. The DEM file was converted to the TIN format using the 3D Analyst toolbox in ArcGIS. Looking for "C:\BMT_WBM\TUFLOW_Dongle_Settings.dcf".not found. HEC-GeoRAS Processing To create the geometric data file for HEC-RAS, HEC-GeoRAS requires a digital terrain model of the river system in the Triangulated Irregular Network (TIN) format. Hazard Routines ID in TUFLOW_USER_DEFINED.dll: Default Hazard Routines Does anybodyhave any ideas? I have copied the tlf output below Įxecutable: Called from external 1D scheme (Copyright BMT WBM Pty Ltd)Ĭompiler: Intel Fortran v11.1 Single Precision 32-bit I dont understand why, as the dongle is plugged in and there is no reason for this. I am stumped as to why it suddenly stops in mid-process and would be very grateful if anybody could point out a reason why?Īfter running TUFLOW successfully and on numerous occasions over the last couple of days, I have suddenly got the message 'TUFLOW Engine Not licensed or no local licences free'. Reading Restart File K:\Projects\13509 - RUTHERGLEN, BAGLAN\DESIGN\WTD_TUFLOW\ruĬlosing GIS Layer 1 .Ĭlosing GIS Layer 2. Reading Restart File K:\Projects\13509 - RUTHERGLEN, BAGLAN\DESIGN\WTD_TUFLOW\ru. Trying to open file K:\Projects\13509 - RUTHERGLEN, BAGLAN\DESIGN\WTD_TUFLOW\runs\common\PT_MHWS_Q1000_WTD_. 'Domain_001: Initialising 2D Data (Stage 2). It never gets to the point at which it starts to simulate results. I then get a 'Premature exit of Tuflow' and cannot seem to find a reason why. The model appears to run through the initial phases, until it gets to the stage copied below. The tcf then reads in a slightly amended tgc which simply reads in a zhape layer representing the proposed development. I have saved both a trf and a erf file in the 'runs' folder in the model folder. I have specified the same start time as that of the restart file. I have saved a copy of the tcf for the 'base' model and asked it to read in the restart file created in the 'base' run. This should prevent the need to run the first half of the model and therefore significantly reduce model run times. I want to make a small change in the 2d domain to represent a proposed development, and then re-start the model at the specified time using the re-start file. I have run a base model and asked it to write out a restart file at a specific time. I have a 1d/2d ESTRY TUFLOW model with a run time of 40 hours (!).